Skip to main content

Silicone Braided Hose

The construction of our braiding Hoses enables silicone tubing to handle increased pressure applications. We offers outstanding resistance to temperature extremes and is made from FDA-sanctioned ingredients. The flexible design and construction of this hoses allows excellent bend radii and permits installation in restricted spaces without impeding flow.
Our Braided Hoses are available in peroxide and platinum cured grade, contains no sulphur or other acid-producing chemicals thereby eliminating the possibility of staining, corroding, or deteriorating other materials it contacts. It is also resistant to ozone and U.V. over long time periods. Care is recommended in the selection of fittings and clamps, as sharp barbed fittings or unlined metal clamps could tear into the hose wall and possibly cause a failure, especially at elevated pressures.
Silicone Braided Hose Adhesive Lines, Beverage Service, Bottle Filling, Deionized Water Transfer,Fermenter Lines, Hot Fill Lines, Food Handling, Laboratory, Resin Feeds, Stirring Vessels, Viscous Material Handling


Comments

Popular posts from this blog

Preparation of barium chloride solution

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 10.0 grams of Barium Chloride LR and transfer slowly, into above said beaker, through it‘s side walls, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 10.0% w/v. Barium Chloride , Distilled water, Glass rod, Glass funnel, Calibrated Analytical Balance

preparation of sodium hydroxide solution dilute

Pour about 75 ml of distilled water into a 250 ml capacity beaker. Weigh 5.0 grams of Sodium Hydroxide Pellets LR and transfer slowly, into above said beaker, through it‘s sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beaker and funnel with few ml of distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 5.0% w/v. Sodium Hydroxide Pellets , glass funnel, sidewalls, glass rod

Operation of Gas Chromatograph

To lay down the procedure for operation of gas chromatograph (SHIMADZU GC-2010 with AOC-5000) system. Shimadzu gc system, gc-2010. Aoc 5000 headspace sampler and auto-injector. 3gc solution software. Ensure that the working bench and area is clean. Always ensure gas line pressure is maintained above 4kg/cm2 in all gas supply lines . Gas Chromatograph , tighten, injection , magnetic force