Skip to main content

Procedure For Medical Checkup

PROCEDURE
All new employees shall be subjected to complete medical checkup as per format no. xxxxx
Employees working in the cephalosporin manufacturing area shall be tested for cephalosporin resistance. The employees who have cephalosporin resistance only shall be allowed to work in those areas.
Occupational exposure (i.e. Chemical Exposure, Noise Exposure etc.,) & Health Effects shall be conducted and data shall be generated during periodical medical examination.
Audiometric Test shall be conducted for the employees who are working in D.G. & Boiler Operations during pre-employment and periodical medical examinations.
Medical checkup shall be conducted for all employees once in a year as per format no. xxxxx
If any employee is found medically unfit, the employee is not allowed to work till he attains medical fitness.
Administration, Procedure, Medical Checkup


Comments

Popular posts from this blog

Preparation of barium chloride solution

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 10.0 grams of Barium Chloride LR and transfer slowly, into above said beaker, through it‘s side walls, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 10.0% w/v. Barium Chloride , Distilled water, Glass rod, Glass funnel, Calibrated Analytical Balance

preparation of sodium hydroxide solution dilute

Pour about 75 ml of distilled water into a 250 ml capacity beaker. Weigh 5.0 grams of Sodium Hydroxide Pellets LR and transfer slowly, into above said beaker, through it‘s sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beaker and funnel with few ml of distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 5.0% w/v. Sodium Hydroxide Pellets , glass funnel, sidewalls, glass rod

Operation of Gas Chromatograph

To lay down the procedure for operation of gas chromatograph (SHIMADZU GC-2010 with AOC-5000) system. Shimadzu gc system, gc-2010. Aoc 5000 headspace sampler and auto-injector. 3gc solution software. Ensure that the working bench and area is clean. Always ensure gas line pressure is maintained above 4kg/cm2 in all gas supply lines . Gas Chromatograph , tighten, injection , magnetic force