Skip to main content

Infrared spectrophotometry

Spectrophotometric tests are commonly used in the Identification of chemical substances and quantification of polymorphic forms. The test procedures are applicable to substances that absorb IR radiation.
The IR absorption spectrum of a substance compared with that obtained concomitantly for the corresponding reference standard / reference substance provide conclusive evidence of the identity of the substance being tested.
Spectrophotometric, potassium chloride, evaporate




Comments

Popular posts from this blog

Preparation of barium chloride solution

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 10.0 grams of Barium Chloride LR and transfer slowly, into above said beaker, through it‘s side walls, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 10.0% w/v. Barium Chloride , Distilled water, Glass rod, Glass funnel, Calibrated Analytical Balance

preparation of sodium hydroxide solution dilute

Pour about 75 ml of distilled water into a 250 ml capacity beaker. Weigh 5.0 grams of Sodium Hydroxide Pellets LR and transfer slowly, into above said beaker, through it‘s sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beaker and funnel with few ml of distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 5.0% w/v. Sodium Hydroxide Pellets , glass funnel, sidewalls, glass rod

Preparation of sodium hydroxide solution

Pour about 75 ml of distilled water into a 250 ml capacity beaker. Weigh 20.0 grams of Sodium Hydroxide Pellets LR and transfer slowly, into above said beaker, though it‘s sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beaker and funnel with few ml of distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 20.0% w/v. SODIUM HYDROXIDE , PREPARATION, distilled water, volumetric flask