To have a written procedure for Electronic data storage and reading. To store and read the Instrumental analytical data in the form of electronic data storage. It is the responsibility of Executive Quality Control to follow this SOP. Copy the required data from the source computer to the destination CD writer CD to be written.
If the data copying is not possible directly, follow the procedure as per the instrument software. Write the copied data from hard disk to CD.
Data Storage, Retrieving, copying, procedure, Precautions


ich

Comments

Popular posts from this blog

Preparation of barium chloride solution

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 10.0 grams of Barium Chloride LR and transfer slowly, into above said beaker, through it‘s side walls, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 10.0% w/v. Barium Chloride , Distilled water, Glass rod, Glass funnel, Calibrated Analytical Balance

Preparation of nitric acid dilute (10 percent)

Measure 10.6 ml of Nitric Acid LR and transfer into a 50.0 ml capacity beaker. Pour about 75.0 ml of distilled water into a 250 ml capacity beaker. Transfer slowly, through sidewalls of the beaker, 10.6 ml of Nitric Acid LR into above said beaker, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beakers and funnel with few ml of distilled water , and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Nitric Acid , Glass rod, Glass funnel, Beaker, Volumetric flask , Measuring cylinders

PREPARATION OF SILVER NITRATE SOLUTION (5 percent )

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 5.0 grams of Silver Nitrate LR and transfer slowly, into above-said beaker, through its sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 5.0% w/v. Silver Nitrate , Glass funnel, Beaker, Distilled water , Glass rod