Prerana Creative Works is a premier animation company, Offers world class services in Animation, VFX & Game Development. With cutting-edge technology, cultural compatibility, solid management & industry experience with cost advantages, Computer Graphics & Animation , established in 2017 with an aim of provided high-quality computer graphic services . Vijayawada business information , prerana creative works -Penamaluru, Penamaluru business information, Prerana Creative Works , VFX ads , 3D&2D ads, Videos Editing , Logo Designing 2D&3D , Shooting , Songs Editing, Prerana Creative Works, VFX ads , 3D&2D ads, Videos Editing , Logo Designing 2D&3D, Shooting , Songs Editing,,12-68/F, Poranki, Penamaluru Center

Ganesh Electrical and Electronics

We Ganesh Electricals & Electronics established as a service provider located in Nutakki Village. We are one of the primary service providers for all types of repairs like bore wells and pumps Fan Repair, TV Repair in, LED Repair, LCD Repair, Mixer Repair, Electrical work, Motor repairing. Infused with the aim to deal in best quality Services. We have made a continuous improvement in the service of various electricals & electronics at your door step. Mangalagiri business information, Ganesh Electrical and Electronics -Nutakki, Nutakki business information, Fan Repair in Nutakki, TV Repair in Nutakki, LED Repair in Nutakki, LCD Repair in Nutakki , Mixer Repair in Nutakki, Electrical works in Nutakki, Motor repairing Repair in Nutakki, Ganesh Electricals & Electronics Near Gopla Seamy Temple, Main Road, Nutakki -522303

Procedure for Cleaning Of Microbiology Laboratory And Preparation Of Disinfectant Solutions

To lay down the Procedure for Cleaning of Microbiology Laboratory and Preparation of Disinfectant Solutions. This Procedure is applies to the Cleaning of Microbiology Laboratory and Preparation of Disinfectant solutions for decontamination. Person from concerned department directly involved in the activity shall be responsible for to ensure proper cleaning of the microbiology area and preparation of disinfectant solutions. Disinfectant Solutions , Microbiology, Cleaning

Replacement of gland packing of pumps and reactors

To describe a standard operating procedure for replacement of gland packing of pumps and reactors. The standard operating procedure describes in detail the method of replacing gland packing of pumps and reactors in the plant. The responsibility of replacing the gland packing of pumps and reactors  lies with the staff of rank not lower than junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager-Maintenance, Head of Production and Head of QAD respectively. Reactors , Pumps , Gland packing , Engineering

Replacement of gaskets of reactors main flange pressure filters and leaf filters

To describe a standard operating procedure for replacement of gaskets of reactors main flange, pressure filters and leaf filters. The standard operating procedure describes in detail the method of replacing gaskets of reactors main flange, pressure filters and leaf filters in the plant. The responsibility of replacing gaskets of reactors main flange, pressure filters and leaf filters lies with the staff of rank not lower than junior utility operator of maintenance department. Leaf filters , Gaskets , Engineering

Replacement of gaskets of pipe lines pumps

To describe a standard operating procedure for replacement of gaskets of pipe lines/pumps. The standard operating procedure describes in detail the method of replacing gaskets of pipe lines/pumps in the plant. The responsibility of replacing gaskets of pipe lines/pumps lies with the staff of rank not lower than junior utility operator of maintenance department. Pipe lines pumps , Replacement of gaskets , Engineering

Dechocking of impeller and replacing corroded impeller refixing of loosened impeller of pumps

To describe a standard operating procedure for dechocking of impeller & replacing corroded impeller/refixing of loosened impeller of pumps. The standard operating procedure describes in detail the method of dechocking of impeller & replacing corroded impeller/refixing of loosened impeller of pumps in the plant. The responsibility of dechocking of impeller & replacing corroded impeller/refixing of loosened impeller of pumps lies with the staff of rank not lower than supervisor of maintenance department. Refixing of Loosened Impeller Of Pumps ,Replacing Corroded Impelle, Engineering

Replacement of spares of mechanical seal unit of pumps

To describe a standard operating procedure for replacement of spares of mechanical seal unit of pumps. The standard operating procedure describes in detail the method of replacing spares of mechanical seal unit of pumps in the plant. The responsibility of replacing the spares of mechanical seal unit of pumps lies with the staff of rank not lower than supervisor of maintenance department. Mechanical seal unit of pumps , Replacement of spares , Engineering, ' O' rings

Replacement of spares of mechanical seal unit of reactors

To describe a standard operating procedure for replacement of spares of mechanical seal unit of reactors. The standard operating procedure describes in detail the method of replacing spares of mechanical seal unit of reactors in the plant. The responsibility of replacing the spares of mechanical seal unit of  reactors lies with the staff of rank not lower than supervisor of maintenance department. Mechanical Seal Unit , Reactors , Engineering

Replacement of damaged couplings pulleys of reactors pumps motors and gear boxes

To describe a standard operating procedure for replacement of damaged couplings/pulleys of reactors, pumps, motors and gearboxes. The standard operating procedure describes in detail the method of replacing damaged couplings/pulleys of reactors, pumps, motors and gearboxes in the plant. The responsibility of replacing the couplings/pulleys of reactors, pumps, motors and gearboxes lies with the staff of rank not lower than junior utility operator of maintenance department. Damaged couplings , Reactors pumps, Motors , Gear boxes

Repairing replacing the agitator shaft of reactors

To describe a standard operating procedure for repairing/replacing of agitator/shaft of reactors. The standard operating procedure describes in detail the method of repairing/replacing of agitator/shaft of reactors in the plant. The responsibility of repairing/replacing of agitator/shaft of reactors lies with the staff of rank not lower than supervisor of maintenance. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Reactors,  Engineering Repairing replacing ,

Welding the damaged jacket of reactor

To describe a standard operating procedure for welding the damage jacket of reactor. The standard operating procedure describes in detail the method of welding the damaged jacket of reactor. This SOP is applicable for welding of damaged jacket of reactor where the production clearance is not available for position welding/hot job and also for position welding where the production clearance available by obtaining welding work permit. Reactor , Engineering  Damaged jacket,

Replacement of valves

To describe a standard operating procedure for replacement of valves. The standard operating procedure describes in detail the method for replacing the valves in the plant. The responsibility of replacing the valves lies with the staff of rank not lower than the junior utility operator. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Replacement of valves , Utility operator, Engineering

Sending out equipment for rectification to the outside agency

To describe a standard operating procedure for sending out equipment for rectification to the outside agency. The standard operating procedure describes in detail the method of sending out equipment for rectification to the outside agency. The responsibility of sending out the equipment lies with the staff of rank not lower than the maintenance engineer. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively.    Rectification , Sending out equipment , Engineering

Breakdown rectification of leaf filters

To describe a standard operating procedure for breakdown rectification of leaf filters. The standard operating procedure describes in detail the method of breakdown rectification of leaf filters in the plant. The responsibility of break down rectification of leaf filters lies with the staff of rank not lower than junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Leaf filters , Engineering, Breakdown rectification

Breakdown rectification of pressure filters

To describe a standard operating procedure for breakdown rectification of pressure filters. The standard operating procedure describes in detail the method of breakdown rectification of pressure filters in the plant. The responsibility of breakdown rectification of pressure filters lies with the staff of rank not lower than junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Pressure filters , Breakdown rectification, Engineering

Replacement of oil seals of gear boxes

To describe a standard operating procedure for replacement of oil seals of gearboxes. The standard operating procedure describes in detail the method of replacing oil seals of gearboxes belongs to Process / Utilities / Laboratory equipments. The responsibility of replacing the oil seals of gearboxes lies with the staff of rank not lower than junior utility operator of maintenance department. Gear Boxes , Engineering

Replacement of bearings of process utilities laboratory equipment

To describe a standard operating procedure for replacement of bearings of process / utilities / laboratory equipment. The standard operating procedure describes in detail the method of replacing the bearings of process / utilities / laboratory equipment. The responsibility of replacing the bearings of process / utilities / laboratory equipment lies with the staff of rank not lower than junior utility operator of maintenance department. Laboratory equipment , Utilities, Engineering

Replacement of coupling bolts of reactors

To describe a standard operating procedure for replacement of coupling bolts of reactors. The standard operating procedure describes in detail the method of replacing coupling bolts of reactors. The responsibility of replacing the coupling bolts of reactors lies with the staff of rank not lower than junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Coupling bolts of reactors , Engineering, coupling guard

Breakdown rectification of sifter

To describe a standard operating procedure for breakdown rectification of sifter. The standard operating procedure describes in detail the method of breakdown rectification of sifter and includes replacement of motor bearings, rectification of burnt motor, replacement of motor pulley and sifter shaft pulley, replacement of spider, replacement of sieve, replacement of sifter bearings and replacement of V-belts. Breakdown rectification , Engineering, Pulleys of reactors , Pumps

Breakdown rectification of blender

To describe a standard operating procedure for breakdown rectification of blender. The standard operating procedure describes in detail the method of breakdown rectification of blender, which includes gear box oil seals leakage, damage of couplings of motor and blender, motor bearings damage and blender bearings damage. The responsibility of carrying out breakdown rectification  of blender lies with staff of rank not lower than the junior utility operator of maintenance department. Breakdown rectification , Engineering, Laboratory equipment

Breakdown rectification of reactors

To describe a standard operating procedure for breakdown rectification of reactors. The standard operating procedure describes in detail the method of breakdown rectification of reactors. The responsibility of breakdown rectification of various reactors lies with the staff of rank not lower than maintenance supervisor of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Breakdown rectification , Engineering, Jacket of reactor

Breakdown rectification of fluid bed dryer

To describe a standard operating procedure for break down rectification of fluid bed dryer. The standard operating procedure describes in detail the method of breakdown rectification of fluid bed dryer. The responsibility of breakdown rectification of fluid bed dryer lies with the staff of rank not lower than maintenance supervisor of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Fluid bed dryer , Engineering

Breakdown rectification of centrifuge

To describe standard operating procedure for breakdown rectification of centrifuge. The standard operating procedure describes in detail the method of breakdown rectification of the centrifuge. The responsibility of breakdown rectification of centrifuge lies with the staff of rank not lower than the supervisor of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Rectification of Centrifuge , Engineering, Isolate

Breakdown rectification of centrifugal pumps

To describe a standard operating procedure for breakdown rectification of centrifugal pumps. The standard operating procedure describes in detail the possible breakdowns and the method of their rectification of centrifugal pumps. The responsibility of breakdown rectification of centrifugal pumps lies with the staff of rank not lower than junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Centrifugal pumps , Engineering, Gear boxes

Breakdown rectification of boiler

To describe a standard operating procedure for breakdown rectification of boiler. The standard operating procedure describes in detail the method of breakdown rectification of boiler. It includes rectification of burnt motor of ID & FD fans, replacement of pulleys of motor and ID fan shaft, replacement of ID fan bearings, replacement of V-belts of ID fan, rectification of steam injector, replacement of couplings of feed water pump and motor, replacement of  bearings of feedwater pump motor , ID & FD fan motor, rectification of short supply and no water supply to boiler. Rectification of boiler , Engineering, Bearings of feedwater pump motor

Breakdown rectification of microniser

To describe a standard operating procedure for breakdown rectification of air jet microniser. The standard operating procedure describes in detail the method for breakdown rectification of microniser. The responsibility of breakdown rectification of microniser lies with the staff of rank not lower than the maintenance engineer. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Rectification of microniser , Engineering, Air jet microniser

Installing the solvent recovery column

To describe a standard operating procedure for installing the solvent recovery column. The standard operating procedure describes in detail the method of installing the solvent recovery column. The responsibility of installing the solvent recovery column lies with the staff of rank not lower than the maintenance engineer. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance,  Head of Production and Head of QAD respectively. Solvent Recovery Column , Engineering

Regeneration and operation of demineralised water plant

To describe standard operating procedure for regeneration and operation of Demineralised water plant. The standard operating procedure describes in detail the method of Regeneration and operation of Demineralised water plant. The responsibility of Regenerating and operating the Demineralised water plant lies with the staff of rank not lower than the chargeman of maintenance department. Demineralised Water Plant , Engineering, Strong Acid

Hydraulic testing of the reactor jacket

To describe a standard operating procedure for hydraulic testing of the reactor jacket. The standard operating procedure describe in detail the method of hydraulic testing of the reactor jacket. The responsibility of carryingout hydraulic test of the reactor jacket lies with the staff of rank not lower than the junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Hydraulic Testing of the Reactor Jacket

Regeneration and operation of soft water plant

To describe standard operating procedure for regeneration and operation of soft water plant. The standard operating procedure describes in detail the method of regeneration and operation of soft water plant. The responsibility of regenerating and operating the soft water plant  lies with the staff of rank not lower than the junior utility operator of maintenance department. The responsibility of preparing, reviewing and approving the standard operating procedure lies with the Manager - Maintenance, Head of Production and Head of QAD respectively. Soft Water Plant , Engineering

Sanitization of D.M Water System And Soft Water System

To describe a standard operating procedure for sanitization of  D.M water system and soft water system. The standard operating procedure describes in detail the method for the sanitization of D.M water system (i.e. Treated Raw water tank, cation bed, anion bed, mixed bed, interconnected pipelines) and soft water system (i.e. Treated Raw water tank, Softener, Soft water storage tank , interconnected lines and soft water transfer pump ) to control the Microbial growth pertaining to its alert/action limits. Soft Water System , D.M Water System , Engineering

Calibration of dial temperature gauges digital temparature indicators controllers

To describe a standard operating procedure for the calibration of Dial temperature gauges with standard zeal thermometers and the calibration procedure for the Digital temperature indicator/controllers with standard RTD simulator. The standard operating procedure describes in detail the method for the calibration of Dial temperature gauges with standard zeal thermometer and Digital temperature indicator/controllers with standard RTD simulator. Temperature Indicators, Temperature Gauges, Engineering

Calibration of Weighing Machines

To describe a standard operating procedure for the calibration of weighing machines. The standard operating procedure describes in detail the method for the calibration of both mechanical and electronic weighing machines in the plant. The procedure holds good for the in-house calibration only. The responsibility of calibrating the weighing machines lies with the staff of rank not lower than the Supervisor of maintenance department. Weighing Machines , Calibration, Engineering

Calibration of pressure gauges

To describe a standard operating procedure for the calibration of pressure gauges. The standard operating procedure describes in detail the method for the calibration of pressure gauges in the plant. He responsibility of calibrating the pressure gauges lies with the staff of rank not lower than the supervisor of maintenance department. The responsibility of preparation, review and approval of the standard operating procedure lies with the Manager (Maintenance), Head of Production and Head of   QAD respectively . Pressure Gauges , Engineering, Particular Gauge