Skip to main content

Cone Penetrometer

It will consist of metallic cone with half angle of 15' -30 ±15' and 30.50mm coned length. It will be fixed at the end of a metallic rod with a disc at the top of the rod so as to have a total sliding weight of 148± 0.5 gms. The total rod shall pass through two guides. (to ensure vertical movement) fixed to a stand. S
uitable provision will be made for clamping the vertical rod at any desired height above the surface of the paste in the trough. A brass trough 50 mm internal diameter and 50 mm depth will be provided as per IS specification resting on M.S.bars.
Optional Accessories
Ground Glass : 10mm thick and about 45 cm square or larger rough glass as per IS 2720 (Part V-1985) for mixing soil and water
Spatula : Flexible with blade about 8 cm long and 2 cm wide made from stainless steel material as per IS:2720 (part V-1985)
Evaporating dish : Made from porcelain material having diameter of about 12 to 15 cm with smooth surface as per IS 2720 (part V-1985)
Cone Penetrometer, 50 mm internal diameter, Flexible with blade, Spatula, Evaporating dish, Ground Glass


Comments

Popular posts from this blog

Preparation of barium chloride solution

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 10.0 grams of Barium Chloride LR and transfer slowly, into above said beaker, through it‘s side walls, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 10.0% w/v. Barium Chloride , Distilled water, Glass rod, Glass funnel, Calibrated Analytical Balance

Preparation of nitric acid dilute (10 percent)

Measure 10.6 ml of Nitric Acid LR and transfer into a 50.0 ml capacity beaker. Pour about 75.0 ml of distilled water into a 250 ml capacity beaker. Transfer slowly, through sidewalls of the beaker, 10.6 ml of Nitric Acid LR into above said beaker, while gentle mixing, by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask by using a glass funnel. Rinse the beakers and funnel with few ml of distilled water , and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Nitric Acid , Glass rod, Glass funnel, Beaker, Volumetric flask , Measuring cylinders

PREPARATION OF SILVER NITRATE SOLUTION (5 percent )

Pour about 75 ml of Distilled water into a 250 ml capacity beaker. Weigh 5.0 grams of Silver Nitrate LR and transfer slowly, into above-said beaker, through its sidewalls, while gentle mixing by using a glass rod. Transfer prepared solution into a 100 ml volumetric flask, by using a glass funnel. Rinse the beaker and funnel with few ml of Distilled water, and allow to add into the contents of volumetric flask. Make up the volumetric flask to mark with Distilled water, remove the funnel, keep the lid to close the volumetric flask and shake gently to mix the solution. Transfer the prepared solution into a suitable container and label with all necessary details. The resultant solution is having the concentration of 5.0% w/v. Silver Nitrate , Glass funnel, Beaker, Distilled water , Glass rod